Technical features
Technical data F84G - standard models
Symbol Port size Drain Filter element Bowl Weight Model
(µm) (kg)
G3/8 Auto 40 Guarded polycarbonate 0,38 F84G-3GN-AP3
G1/2 Auto 40 Guarded polycarbonate 0,38 F84G-4GN-AP3
G3/4 Auto 40 Guarded polycarbonate 0,38 F84G-6GN-AP3
G3/8 Auto 40 Metal with level indicator 0,52 F84G-3GN-AD3
G1/2 Auto 40 Metal with level indicator 0,52 F84G-4GN-AD3
G3/4 Auto 40 Metal with level indicator 0,52 F84G-6GN-AD3
G3/8 Manual 40 Guarded polycarbonate 0,38 F84G-3GN-QP3
G1/2 Manual 40 Guarded polycarbonate 0,38 F84G-4GN-QP3
G3/4 Manual 40 Guarded polycarbonate 0,38 F84G-6GN-QP3
G3/8 Manual 40 Metal with level indicator 0,52 F84G-3GN-QD3
G1/2 Manual 40 Metal with level indicator 0,52 F84G-4GN-QD3
G3/4 Manual 40 Metal with level indicator 0,52 F84G-6GN-QD3
> Port size: 3/8” ... 3/4”
(ISO G/PTF)
> Excelon
®
Plus design
allows in-line
installation or modular
installation with other
Excelon
®
Plus products
> 5 or 40 micron particle
and high eciency
water removal (> 98%)
> Double safety lock
bowl
> Metal bowl with
prismatic liquid level
indicator lens
> Light weight
polycarbonate bowl
> Air purity classes in
accordance to
ISO8573-1: particles
class 6 & 7 and liquid
water class 8
Medium:
Compressed air only
Maximum supply pressure:
Polycarbonate bowl: 10 bar (145 psi)
Metal bowl: 20 bar (290 psi)
Filter element:
5 μm & 40 μm
Port size:
G3/8, G1/2, G3/4,
3/8 PTF, 1/2 PTF, 3/4 PTF
Flow:
78 dm
3
/s
at port size: 1/2”,
operating pressure 6,3 bar (91 psi)
and a Δp: 0,5 bar (7,25 psi) drop
from set.
Filter element: 40 μm
Drain:
Manual or automatic
Automatic drain operating
conditions (float operated):
Bowl pressure required to close
drain: > 0,35 bar (5 psi)
Bowl pressure required to open
drain: ≤ 0,2 bar (2,9 psi)
Minimum air flow required to close
drain: 1 dm
3
/s (2 scfm)
Ambient/Media temperature:
Polycarbonate bowl:
-10 ... +60ºC (14 ... +140ºF)
Metal bowl:
-20 ... +65ºC (-4 ... +149ºF)
Air supply must be dry enough
to avoid ice formation at
temperatures below +2°C (+35°F).
Materials:
Body: Die cast aluminium
Body covers: ABS
Bowl: Transparent PC with PP
guard or die cast aluminium
Liquid level indicator lens
(metal bowl): PA
Filter element: sintered PP
Bowl ‘o’- ring: Chloroprene
Elastomers: NBR
F84G-˙˙N-˙˙˙
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Pressure drop
Air flow (dm³/s)
F84G - 40 Microns - 10 bar
2.5
4.0
8.0
6.3
10
1.6
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
Pressure drop
Air flow (dm³/s)
F84G - 5 Microns - 10 bar
2.5
4.0
8.0
6.3
10
1.6
F84G - Excelon® Plus Modular System
General purpose filter
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
en 8.200.150.02
11/17
Option selector
Port size Substitute
3/8” 3
1/2” 4
3/4”
6
Thread form Substitute
PTF A
ISO G parallel (standard) G
Drain Substitute
Manual (standard) Q
Auto drain (standard) A
Element Substitute
5 µm 1
40 µm (standard) 3
Bowl Substitute
Transparent with guard (standard) P
Metal with liquid indicator
(optional)
D
Flow characteristics
Pressure drop Δp (bar)
Air flow (dm
3
/s)
Element 40 µm
Port size: 1/2”
Pressure drop Δp (bar)
Air flow (dm
3
/s)
Element 5 µm
Port size: 1/2”
Inlet pressure
Inlet pressure
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
F84G - Excelon® Plus Modular System
General purpose filter
en 8.200.150.03
11/17
Full flow porting block
3/4 PTF
Full flow porting block
G3/4
Pressure switch interface
block (18D pressure switch)
Pneumatic pressure switch
18D (0,5 ... 8 bar) *1)
Digital pressure switch
51D (-1 ... 10 bar) *2)
Page 6 Page 6 Page 7 Page 7 Page 7
840028-50KIT 840028-53KIT 0337717000000000 0881300 0860810
*1) Flanged version. For other pressure ranges, please see data sheet 5.11.001
*2) For other pressure ranges, please see data sheet 5.11.385
Port Adaptors
3/8 PTF
Port Adaptors
1/2 PTF
Port Adaptors
3/4 PTF
Port Adaptors
G3/8
Port Adaptors
G1/2
Port Adaptors
G3/4
Page 7 Page 7 Page 7 Page 7 Page 7 Page 7
840015-02KIT 840015-03KIT 840015-04KIT 840015-10KIT 840015-11KIT 840015-12KIT
Accessories
Wall mounting bracket Quikclamp
®
Quikclamp
®
with bracket assembled
Pressure sensing block
1/4 PTF
Pressure sensing block
G1/4
Page 6 Page 6 Page 6 Page 6 Page 6
840024-50KIT 840014-51KIT 840014-52KIT 840016-50Kit 840016-51KIT
F84G - Excelon® Plus Modular System
General purpose filter
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
en 8.200.150.04
11/17
Maintenance/Service
Filter cartridge
5 micron
Filter cartridge
40 micron
Auto drain kit with
metal Nut - Imperial
Auto drain kit with
metal Nut - Metric
840038-50KIT 840038-51KIT 6000-61KIT 6000-60KIT
Spare parts
Filter Bowl
(Guarded Poly bowl with
auto drain 6 mm PIF)
Filter Bowl
(Guarded Poly bowl with manual
drain)
Filter Bowl
(Metal with S/Glass & auto drain,
6 mm PIF)
Filter Bowl
(Metal with S/Glass &
manual drain)
840025-51KIT 840025-50KIT 840003-51KIT 840003-50KIT
Filter Bowl
(Guarded Poly bowl with
auto drain, 1/4 PIF)
Filter Bowl
(Metal with S/Glass &
auto drain, 1/4 PIF)
840025-53KIT 840003-56KIT
70
73
205
# 25
36
36
208
176
29
3
1
2
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
F84G - Excelon® Plus Modular System
General purpose filter
en 8.200.150.05
11/17
Dimensions
Dimensions in mm
Projection/Third angle
Automatic Drain
1/4 Turn Manual Drain
# Minimum clearance for bowl removal
1
Main ports 3/8”, 1/2” or 3/4”
(ISO G/PTF)
2
Transparent bowl with guard
3
Metal bowl with liquid level indicator
lens
71
5
8
8.9 15
4
7
15
58
3
6
5
7
66
4
18
2
9
31
56
11.5
60
47
49
76
119
54
14
4
5
7
51
54.3
5
1
2
1
33
45
80 51
5
7
4
6
68
F84G - Excelon® Plus Modular System
General purpose filter
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
en 8.200.150.06
11/17
Dimensions in mm
Projection/Third angle
Accessories
Mounting bracket
Quikclamp
®
Quikclamp
®
with wall bracket
Pressure sensing block
Full flow porting block
44
32
40
40
G1/2
5
30
3
0
4
5
1
8
A
/C
27
.
5
72
35
44
32
40
57
G1/2
40
38.5
3
8
.
5
18
80 51
5
7
4
6
68
~300 31
1
3
56
4
7
31
G1/8
36,5
~30
2
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
F84G - Excelon® Plus Modular System
General purpose filter
en 8.200.150.07
11/17
18D Pressure switchPorting block for
18D pressure switch
18D Porting block and
18D assembled
Pipe adaptor
51D Pressure switch - digital
Dimensions in mm
Projection/Third angle
1
Switch OUT 1, green LED
2
Switch OUT 2, red LED
3
Dustproof protector
4
Connector M12 x 1
5
Inlet port
6
Alternative inlet port G1/8 plugged
7
Thread for mounting screw
F84G - Excelon® Plus Modular System
General purpose filter
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2017 - 9213a) © 2015 Norgren Ltd
en 8.200.150.08
11/17
Warning
These products are intended for use in industrial compressed air systems
only. Do not use these products where pressures and temperatures can
exceed those listed under »
Technical features/data«.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems or other applications not
within published specifications, consult
IMI Precision Engineering, Norgren Ltd.
Through misuse, age, or malfunction, components used in fluid power
systems can fail in various modes. The system designer is warned to
consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury
or damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system
instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.
EN - Englisch